[Installer] Cancel a silent upgrade when the running-instance guard fails
The running instance guard is what stands between a locked install directory and the mixed Qt DLL set that breaks the next start, but it failed open in two places and let the install carry on anyway: - powershell.exe could not be started: the check warned and returned - the process lookup answered "could not determine": WaitForAppToClose returned on $R0 != 1, so "unknown" was treated exactly like "not running" On a silent upgrade there is nobody at the keyboard to close the applications in response to that warning, which is precisely the state in which the launcher was still holding its Qt DLLs mapped. - Treat "could not determine" as its own state rather than folding it into "not running", in all three places WaitForAppToClose inspects the result - Cancel a silent upgrade in both cases; keep an interactive install on the existing warn-and-continue path, since refusing there would leave an installer that can never complete and the stale-runtime check still applies - Route every abort through one AbortInstall so the dialog-vs-silent decision lives in a single place, and stop the two pre-existing warning dialogs that a /S install without /R would have blocked on forever
This commit is contained in:
parent
844a1a9b3e
commit
8f6fcdbe83
1 changed files with 81 additions and 29 deletions
|
|
@ -18,6 +18,7 @@ Var OldUninstallString
|
|||
Var StaleFindHandle
|
||||
Var StaleFindName
|
||||
Var IsUpgrade
|
||||
Var AbortReason
|
||||
|
||||
!include LogicLib.nsh
|
||||
!include FileFunc.nsh
|
||||
|
|
@ -334,8 +335,13 @@ Function WaitForAppToClose
|
|||
Call IsAppRunning
|
||||
; Only a definite "running" is worth waiting for. "Not running" is done, and
|
||||
; "could not determine" must not keep the installer waiting on an answer it
|
||||
; will never get - EnsureAppsNotRunning has warned about that case already.
|
||||
${If} $R0 != 1
|
||||
; will never get - but it cannot simply be waved through either, see
|
||||
; HandleUnknownAppState.
|
||||
${If} $R0 = 0
|
||||
Return
|
||||
${EndIf}
|
||||
${If} $R0 = 2
|
||||
Call HandleUnknownAppState
|
||||
Return
|
||||
${EndIf}
|
||||
|
||||
|
|
@ -354,7 +360,8 @@ Function WaitForAppToClose
|
|||
DetailPrint "$R1 closed."
|
||||
Return
|
||||
${EndIf}
|
||||
${If} $R0 != 1
|
||||
${If} $R0 = 2
|
||||
Call HandleUnknownAppState
|
||||
Return
|
||||
${EndIf}
|
||||
System::Call 'kernel32::GetTickCount()i.s'
|
||||
|
|
@ -369,18 +376,9 @@ Function WaitForAppToClose
|
|||
; update and preserves the user's data.
|
||||
${If} $AllowForceClose = 0
|
||||
DetailPrint "$R1 is still running after 60 s; aborting the update so that no data is lost."
|
||||
; The in-app updater runs this installer silent and detached and
|
||||
; never looks at its exit code, so a plain Abort would leave the user
|
||||
; with no update and no explanation. A /S install without /R on the
|
||||
; other hand is unattended - by a package manager, for instance -
|
||||
; and a message box there would block forever, so that case only
|
||||
; reports through the log and the exit code.
|
||||
${If} $ReinstallMode = 1
|
||||
MessageBox MB_OK|MB_ICONEXCLAMATION \
|
||||
"$R1 did not close within 60 seconds, so the installation was aborted to avoid losing unsaved data.$\r$\n$\r$\nPlease close $R1 and run the installer again."
|
||||
${EndIf}
|
||||
SetErrorLevel 1
|
||||
Abort
|
||||
StrCpy $AbortReason \
|
||||
"$R1 did not close within 60 seconds, so the installation was aborted to avoid losing unsaved data.$\r$\n$\r$\nPlease close $R1 and run the installer again."
|
||||
Call AbortInstall
|
||||
${EndIf}
|
||||
; Oracle and Servatrice are console applications: CloseMainWindow()
|
||||
; returned false for them and waiting longer cannot help. They hold no
|
||||
|
|
@ -393,16 +391,14 @@ Function WaitForAppToClose
|
|||
DetailPrint "$R1 closed."
|
||||
Return
|
||||
${EndIf}
|
||||
${If} $R0 != 1
|
||||
${If} $R0 = 2
|
||||
Call HandleUnknownAppState
|
||||
Return
|
||||
${EndIf}
|
||||
DetailPrint "$R1 is still running after 60 s; aborting the update."
|
||||
${If} $ReinstallMode = 1
|
||||
MessageBox MB_OK|MB_ICONEXCLAMATION \
|
||||
"$R1 could not be stopped, so the installation was aborted.$\r$\n$\r$\nPlease close $R1 and run the installer again."
|
||||
${EndIf}
|
||||
SetErrorLevel 1
|
||||
Abort
|
||||
StrCpy $AbortReason \
|
||||
"$R1 could not be stopped, so the installation was aborted.$\r$\n$\r$\nPlease close $R1 and run the installer again."
|
||||
Call AbortInstall
|
||||
${Else}
|
||||
ck_wait_prompt:
|
||||
MessageBox MB_RETRYCANCEL|MB_ICONEXCLAMATION|MB_DEFBUTTON1 \
|
||||
|
|
@ -412,7 +408,8 @@ Function WaitForAppToClose
|
|||
${If} $R0 = 0
|
||||
Return
|
||||
${EndIf}
|
||||
${If} $R0 != 1
|
||||
${If} $R0 = 2
|
||||
Call HandleUnknownAppState
|
||||
Return
|
||||
${EndIf}
|
||||
Goto ck_wait_prompt
|
||||
|
|
@ -421,12 +418,55 @@ Function WaitForAppToClose
|
|||
${EndIf}
|
||||
FunctionEnd
|
||||
|
||||
; A process lookup came back "could not determine": powershell.exe ran but the
|
||||
; answer was not usable, e.g. the process could not be inspected at all. That
|
||||
; state is fine to carry on from when the user is at the keyboard - they can
|
||||
; close the applications by hand and the stale-runtime check still stands
|
||||
; between a failed guard and a mismatched install.
|
||||
;
|
||||
; It is not fine on a silent upgrade. There the whole point of this guard is to
|
||||
; know that nothing holds locks on the files about to be replaced, and this is
|
||||
; exactly the state where that is unknown, with no one to click a dialog: the
|
||||
; old code returned and let the install carry on into the mixed Qt DLL set that
|
||||
; made the next start fail. Cancel the update instead; the next attempt runs
|
||||
; with the applications closed and succeeds.
|
||||
Function HandleUnknownAppState
|
||||
${If} $ReinstallMode = 1
|
||||
StrCpy $AbortReason \
|
||||
"The installation was cancelled because it could not determine whether Cockatrice is still running.$\r$\n$\r$\nPlease close Cockatrice, Oracle and Servatrice and run the installer again."
|
||||
Call AbortInstall
|
||||
${EndIf}
|
||||
DetailPrint "Could not determine whether $R1 is running; close Cockatrice, Oracle and Servatrice manually if the installation reports a problem."
|
||||
${IfNot} ${Silent}
|
||||
MessageBox MB_OK|MB_ICONEXCLAMATION \
|
||||
"This installer could not determine whether $R1 is still running.$\r$\n$\r$\nPlease close Cockatrice, Oracle and Servatrice manually before continuing."
|
||||
${EndIf}
|
||||
FunctionEnd
|
||||
|
||||
Function EnsureAppsNotRunning
|
||||
; guards the install directory
|
||||
StrCpy $GuardDir $INSTDIR
|
||||
Call GuardAppsNotRunning
|
||||
FunctionEnd
|
||||
|
||||
; Aborts the installation, showing $AbortReason to the user.
|
||||
;
|
||||
; Every abort goes through here so the unattended case is handled the same way
|
||||
; everywhere: the in-app updater runs this installer silent and detached and
|
||||
; never looks at its exit code, so a plain Abort would leave the user with no
|
||||
; update and no explanation, while a /S install without /R is unattended - by a
|
||||
; package manager, for instance - and a message box there would block forever.
|
||||
; Only the first of those two gets a dialog; the second reports through the log
|
||||
; and the exit code.
|
||||
Function AbortInstall
|
||||
${If} $ReinstallMode = 1
|
||||
${OrIfNot} ${Silent}
|
||||
MessageBox MB_OK|MB_ICONEXCLAMATION "$AbortReason"
|
||||
${EndIf}
|
||||
SetErrorLevel 1
|
||||
Abort
|
||||
FunctionEnd
|
||||
|
||||
Function EnsureOldInstallNotRunning
|
||||
; Guards the directory of a *previous* installation, as recorded in the
|
||||
; registry. Needed by componentsPagePre, which runs the old uninstaller
|
||||
|
|
@ -450,13 +490,25 @@ Function GuardAppsNotRunning
|
|||
Call IsProcessLookupAvailable
|
||||
${If} $R0 = 0
|
||||
; Without PowerShell we cannot tell whether a running instance is
|
||||
; holding locks on the files we are about to replace. Warn once and
|
||||
; continue: refusing to install would leave the user with an installer
|
||||
; that can never complete, which is worse than the locked-file failure
|
||||
; this check exists to prevent. MessageBox is shown even in a silent
|
||||
; install - the user has to be told to close the applications by hand.
|
||||
; holding locks on the files we are about to replace.
|
||||
DetailPrint "Could not start powershell.exe; skipping the running instance check. Close Cockatrice, Oracle and Servatrice manually if the installation reports a problem."
|
||||
MessageBox MB_OK|MB_ICONEXCLAMATION "This installer could not check whether Cockatrice is still running, because powershell.exe could not be started.$\r$\n$\r$\nPlease close Cockatrice, Oracle and Servatrice manually before continuing."
|
||||
; On a silent upgrade that used to be a warning and nothing more, which
|
||||
; left the very process that launched the installer free to go on
|
||||
; replacing files it still had mapped - the one outcome this guard exists
|
||||
; to prevent - and then writing the new payload on top of them. Cancel
|
||||
; instead. An interactive install can still continue: the user is at the
|
||||
; keyboard, and refusing outright would leave them with an installer that
|
||||
; can never complete.
|
||||
${If} $ReinstallMode = 1
|
||||
StrCpy $AbortReason \
|
||||
"The installation was cancelled because it could not check whether Cockatrice is still running, because powershell.exe could not be started.$\r$\n$\r$\nPlease close Cockatrice, Oracle and Servatrice and run the installer again."
|
||||
Call AbortInstall
|
||||
${EndIf}
|
||||
; The user has to be told to close the applications by hand, but a /S
|
||||
; install without /R is unattended and would block on this forever.
|
||||
${IfNot} ${Silent}
|
||||
MessageBox MB_OK|MB_ICONEXCLAMATION "This installer could not check whether Cockatrice is still running, because powershell.exe could not be started.$\r$\n$\r$\nPlease close Cockatrice, Oracle and Servatrice manually before continuing."
|
||||
${EndIf}
|
||||
Return
|
||||
${EndIf}
|
||||